Computer-Aided controlling-diagnostic laboratory |
 |
|
System Functionality
It can be used:
- when conducting dynamic monitoring of digital and digital-to-analog devices including those that contain microprocessor in manufacturing, maintenance and electronics repairing;
- as a work station for an electronics developer when designing and debugging control tests and diagnostic programs;
- for control and registration in technological nonstop-actions bound to accurate time markers.
Performance specifications
- amount of digital control bypass channels - from 32 up to 256;
- amount of various test sets - up to 8192;
- rate of test sets changing is in 2,44 kHz up to 5 MHz range when using internal oscillator or with the external oscillator frequency;
- modes:
- one-pass or cycle testing with impact input and response registration;
- cycle testing free of response registration;
- step-by-step and testing at a certain beat breakpoint with a timer or operator activity duration;
- cycle test feeding with channel grading;
- signature analyzer;
- logical analyzer;
- arbitrary shaped signals oscillator;
- signals frequency, levels, shaper statistic parameters controlling;
- parameters:
- input/output change at sets change rate;
- responses masking;
- internal or external frequency timing synchronization;
- processes display on the screen as timing charts;
- output signal levels in 3 up to 15 V range;
- calibration of two input signal levels in 0.1 up to 20 V range;
Summary:
It is designed as a set of PC compatible modules with a printed board size equal to 115 - 200 mm built in an office or industrial computer. It can operate in the off-line mode or in local networks; It allows reconfiguration and expansion of a functional capabilities and controlled parameters ranges by using additional boards and adapters; It is a portable and inexpensive system providing high performance of monitoring operations and fault tracing. It does not require high skilled personnel.